Lg Air Conditioner
C2 or CH2 - Outdoor temperature sensor open or closed circuit Display
C4 or CH4 - Heat sink temperature sensor open or closed circuit Display
C5 or CH5 - Communicationindoor and outdoor units Display
C6 or CH6 - Excessive current at inverter DC power circuit Display
C7 or CH7 - Excessive compressor current Display
C8 or CH8 - Indoor fan not rotating.
C9 or CH9 - Outdoor fan not rotating. Display
CA or CH10 - Faulty discharge thermistor Display
CA - Discharge temp more than130 °C 2. Faulty discharge thermistor Display
CC - EEPROM error Display
CD - Inverter module error Display
Po - System in Power Mode – not a fault Display
Lo - System in test mode – not a fault Display
Error41 - Inverter Compressor discharge Thermistor fault
Error 44 - Outdoor unit air Thermistor
Error 45 - condenser coil outlet Thermistor
Error 46 - compressor suction Thermistor
Error 47 - Inverter Compressor discharge Thermistor fault
Error 39 - PCB defect / Wiring defect/ODU Inverter PCB assembly damag
Error 01- Indoor unit return air Thermistor
Error 02 - Indoor unit coil inlet Thermistor
Error 03 - wiring error between the remote controller and the fan coil
Error 04 - float switch fan
Error 05 - communicatio indoor and outdoor
Error 06 - Indoor unit coil outlet Thermistor
Error 09 - EEPROM connects on Main PCB
Error 10 - Indoor Fan Motor problem
Error 21 - over current in the inverters DC power circuit
Error 22 - Compressor over-current see code
Error 25 - incoming power supply to the system.
Error 26 - inverter compressor,indicates a seized compressor.
Error 27 - inverter module, see section on testing
Error 28 - DC Voltageinverter is too high.
Error 29 - Overload operation/Compressor damage/ Motor damage/Input Voltage Low/ODU Inverter PCB assembly damage
Error 32 - Inverter compressor discharge temperature is high (above 105ºC)
Error 73 Overload operation/Compressor damage/ Motor damage/Input Voltage Low/ODU Inverter PCB assembly damage
Error 67 - Outdoor Fan Motor
Errore 65 - Inverter PCB heat sink thermisto
Error 62 - outdoor unit Inverter heat-sinkt hermistor
Error 61 - Indicates the outdoor unit condenser coil temperature is high above 65ºC,